CAEPIPE Version 12.20
CAEPIPE Version 12.20
New feature is added to perform Random Vibrarion Analysis in CAEPIPE. This feature is available for Piping Code = NONE. Refer to the Section titled "Random Vibration" in CAEPIPE Technical Reference Manual as well as in CAEPIPE User's Manual for further details.
Following new piping codes are added. Refer to Piping Code Compliance section of CAEPIPE Code Compliance Manual for more details.
ASME NM.1 (2022)
ASME NM.1 (2022)
EN 13941-1:2019+A1:2021
New feature is added to find the section property from the first occurance of the succeeding elements or from the first occurance of the preceeding elements when the Flange Library dialog is not able to get section property from the current element to obtain the Flange Weight.
Support Load Summary results will show the displacements results for all types of supports.
Shape Factor input field in Wind dialog is applicable only for "Velocity vs Elevation". Hence, Shape Factor input field is disabled in the Wind dialog when the option "Pressure vs Elevation" is selected.
New feature is added to Enable or Disable Dynamic Zoom in Graphics Window while using mouse scroll button for Zoom. This option can be modified through CAEPIPE Main Frame > Preferences > Disable Dynamic Zoom.
New feature is added for translating and rotating the graphics in Graphics Window using a mouse. In Translation mode (Pan), use Mouse Middle Button Down and Drag in Horizontal or Vertical direction for Horizontal or Vertical Translations. Similarly, in Rotation mode (Turn), use Mouse Middle Button Down and Drag in Horizontal or Vertical direction for Rotation in Horizontal or Vertical plane.
New feature is added for transforming Limit Stop loads from Local Coordinate System (LCS) to Global Coordinate System (GCS). Refer to the Section titled "Support Loads" under Results Window in CAEPIPE User's Manual for further details.
MBF format is updated to be compatible with CAEPIPE Version 12.20. See Appendix A of CAEPIPE User's Manual for details.
CAEPIPE User's Manual, Technical Reference Manual, Code Compliance Manual and Verification Manual have been enhanced and updated to be in line with software version 12.20. These Manuals can be downloaded from the link www.sstusa.com/caepipe-docs.
Bug Correction: Auto-refinement of Branches was adding a small element at Branch SIF locations when it is a Skewed line upon every model save.
Bug Correction: Responding to "Save changes" dialog was not performing any action when the command "Analyze" was selected without saving the model.
Bug Correction: For Piping Code = NONE, in von Mises stress computation, CAEPIPE was using the In-plane and Out-of-plane SIFs corresponding to the "From" Node for the "To" Node also. This bug exists from CAEPIPE Versions 5.10 through 12.10. This bug would affect results only when the NONE code is selected and two different values for "User SIF" are entered for the two ends of a component.
Related Release Notes
CAEPIPE and CAEPIPE 3D+ Version 15.10
ASME B31.9 code is updated to ASME B31.9 (2025). Refer to the Piping Code Compliance Section titled ASME B31.9 (2025) in CAEPIPE Code Compliance Manual for details.Added the follow...
CAEPIPE and CAEPIPE 3D+ Version 15.00
Following new piping codes are added. Refer to Piping Code Compliance section of CAEPIPE Code Compliance Manual for more details.ASME B31.8 (2025)EN 13480-3 (2024)CSA Z662 (2023)Ne...
Come see us at Daratech Plant 2007
Come see us at daratech PLANT2007 (Jan 29-31, 2007). We will be debuting https://www.sstcae.com/check-stress, a new product for plant design software users and vendors, the ONLY on...